  "schemaVersion": 1,
  "kind": "datacenter-historical-campus-model-diagnostics",
  "builtAt": "2026-10-01T19:16:11.512Z",
  "methodVersion": "2026-10-load-development-v17",
  "identity": {
    "schemaVersion": 2,
    "methodVersion": "2026-10-load-development-v17",
    "modelFingerprint": "35425aaa8faaf1f45cd09bca565e76d3e958c5fdf2d7abb8f6a8954cf26ab82f",
    "dataFingerprint": "ac33af6875dbfdea22afc81ebc11ca0b20e01ee2b0037e0a14b82550bde5a851"
  },
  "benchmarkSha256": "b067989139fa1e9188320b8672f523fba2346fab2d10dea3027a350a98aebae3",
  "runtimeSeconds": 118.49429190000001,
  "scope": "Four deliberately selected historical CEC project records for semantic and engineering-screen diagnostics. They are not a representative holdout sample, current service reservations, measured bills or proof of regional ranking accuracy.",
  "limitations": [
    "IT MW, facility maximum MW, expected facility demand, generator ratings and service MVA are separate quantities. No MVA-to-MW conversion is made.",
    "A historical named utility and electrical architecture do not confirm spare capacity or a connection agreement for another project at the same coordinates.",
    "Expected leased demand is not an observed annual load factor. Annual billing scenarios retain an explicit assumed load profile.",
    "Campus acreage includes dated project boundaries; a site plan can differ from generic rack, yard and coverage assumptions.",
    "Two coordinates are previously published Cleanview map points with unverified accuracy. Their primary CEC project specifications are reviewed separately. Geographic comparisons must not be interpreted as exact parcel validation.",
    "Permit, construction, operation, utility commitment and commercial availability are not inferred from an SPPE docket."
  ],
  "summary": {
    "campuses": 4,
    "assertions": 46,
    "passed": 46,
    "failures": [],
    "predictiveValidation": false,
    "weightsTuned": false,
    "architectureCoefficientsCalibrated": false,
    "conclusion": "Semantic regression and historical architecture diagnostics only. Four selected campuses cannot validate statewide developer rankings or substitute for utility, water, land and carrier commitments."
  },
  "records": [
    {
      "id": "cec:19-SPPE-01",
      "name": "Laurelwood Data Center",
      "location": {
        "lat": 37.38396,
        "lon": -121.96575,
        "quality": "approximate-interior-point-from-docket-layout",
        "basis": "Selected interior NAD83 UTM zone 10 point E591560/N4137970 from the plotted facility fenceline, transformed to WGS84. Not a surveyed centroid or parcel polygon.",
        "sourceId": "laurelwood-layout"
      },
      "reported": {
        "itNameplateMw": null,
        "facilityMaximumMw": 99,
        "expectedFacilityDemandMw": null,
        "referencePue": 1.25,
        "rackDensityKw": 10,
        "serviceMva": null,
        "installedTransformerMva": 150,
        "serviceKv": 60,
        "utilityAcronym": "SVP",
        "siteAcres": 12,
        "siteAcresBasis": "Approximately 12 acres in the final decision",
        "buildingStories": 4,
        "grossBuildingFloorSqft": 628544,
        "buildingCount": 2,
        "backupGeneratorCount": 56,
        "backupGeneratorNameplateMwEach": 3,
        "backupArchitecture": "Grouped five-to-make-four generators; three 50 MVA substation transformers, two needed for customer load, fed from the SVP 60 kV northwest loop.",
        "utilityCircuitCount": null,
        "currentSpareServiceMw": null,
        "currentCommittedServiceYear": null
      },
      "sources": [
        {
          "id": "laurelwood-final",
          "title": "CEC Final Commission Decision, TN232394",
          "date": "2020-03-13",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=64398&tn=232394",
          "pages": "PDF7/10/12; printed2/5/7",
          "supports": [
            "facilityMaximumMw",
            "siteAcres",
            "buildingStories",
            "grossBuildingFloorSqft",
            "buildingCount",
            "backupGeneratorCount",
            "backupGeneratorNameplateMwEach",
            "serviceKv",
            "utilityAcronym",
            "installedTransformerMva",
            "backupArchitecture"
          ]
        },
        {
          "id": "laurelwood-rebuttal",
          "title": "Applicant rebuttal testimony, TN230258",
          "date": "2019-10",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=61803&tn=230258",
          "pages": "printed7",
          "supports": [
            "referencePue",
            "rackDensityKw"
          ]
        },
        {
          "id": "laurelwood-layout",
          "title": "Applicant data response set1B, TN228854",
          "date": "2019-06-27",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=60191&tn=228854",
          "pages": "PDF86; AppendixDR32-B Figure1",
          "supports": [
            "location"
          ]
        }
      ],
      "variants": {
        "genericArchitecture": {
          "scope": "Same MW and PUE with generic architecture / automatic map utility",
          "knownInputs": [
            "location",
            "facility maximum MW",
            "larger firm-design requirement",
            "design reference PUE"
          ],
          "assumedInputs": [
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Default conditional primary tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.38396,
            "lon": -121.96575,
            "mw": 99,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": null,
            "batteryDuration": 4,
            "loadPue": 1.25,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "primary",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "facility",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 99,
              "loadRackDensityKw": 30,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 2,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "insufficient-data",
            "methodVersion": "2026-10-load-development-v17",
            "score": null,
            "evidenceScore": 22.6,
            "evidenceCoveragePct": 25.3,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": true,
              "economics": false,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "requires-confirmation",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "unknown",
                "observed": null,
                "required": 14.06,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 99,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 950.4000000000003,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "facility",
              "itNameplateMw": 79.2,
              "facilityReferenceMw": 99,
              "operatingPeakMw": 89.1,
              "firmServiceRequirementMw": 99,
              "annualFacilityMwh": 780515.9999998774,
              "annualItMwh": 624412.800000138,
              "fullBuildPeakDayM3": 950.4000000000003
            },
            "utility": {
              "mapStatus": "ambiguous",
              "mappedProviders": [
                "PG&E",
                "SVP"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": null,
              "selection": {
                "provider": null,
                "status": "ambiguous",
                "requested": null,
                "explicitlySelected": false,
                "confirmed": false
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 99,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "No utility-matched preferred POI",
              "kv": null,
              "distanceKm": null,
              "demandMw": 99,
              "capacityConfirmed": false,
              "owner": null,
              "ownerMatchStatus": null,
              "ownershipGate": {
                "providerAcronym": null,
                "providerName": null,
                "status": "utility-unresolved",
                "matchedCount": 0,
                "unresolvedCount": 372,
                "differentUtilityCount": 0,
                "nearbyCount": 757,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Raymond",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.20492941038623,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Scott",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.2747757541958507,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Kenneth",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.3570159096700245,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Duane",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.4847902237064483,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Kifer",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.5513948250219198,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Don Van Raesfeld",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.562353397320421,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Lafayette",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.5830981072979897,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Juliette",
                  "owner": "SVP",
                  "kv": 60,
                  "distanceKm": 0.33068944080682583,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": null,
              "estimatedRequiredAcres": 14.06,
              "fitRatio": null,
              "grossFloorAreaSqft": 227333.78800090932,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 79.2,
                "facilityReferenceMw": 99,
                "facilityDesignMw": 99,
                "racks": 2640,
                "whiteSpaceM2": 10560,
                "grossFloorAreaM2": 21120,
                "buildingFootprintM2": 10560,
                "hallZoneM2": 23466.666666666668,
                "coolingYardM2": 9504,
                "electricalYardM2": 7920,
                "backupYardM2": 7920,
                "otherYardAcres": 2,
                "requiredAcres": 14.061378406333318,
                "acresPerMw": 0.14203412531649817,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "unresolved",
              "schedule": null,
              "annualCostUsd": null,
              "annualKwh": null,
              "dollarsPerMwh": null,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 158057215.4374,
                  "dollarsPerMwh": 202.50349184052604,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 150023107.09739998,
                  "dollarsPerMwh": 192.2101623764279,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 117848186.08425002,
                  "dollarsPerMwh": 150.98753399577973,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "SVP",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 111824324.10336,
                  "dollarsPerMwh": 143.26973963808558,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "project-land",
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 98.6,
                "coverage": 5,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 94.9,
                "coverage": 55,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 84.1,
                "coverage": 65,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": null,
                "coverage": 0,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": false,
            "historicalServiceKv": 60,
            "selectedMappedPoiKv": null,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": null,
            "referenceFacilityMw": 99,
            "reportedWorstCaseFacilityMw": 99,
            "reportedExpectedDemandMw": null,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": null,
            "modeledVsReportedGrossFloorAreaRatio": 0.36168317253988475,
            "modeledRequiredVsReportedCampusAcresRatio": 1.1716666666666666,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        },
        "documentedBrief": {
          "scope": "Source-informed historical design scenario",
          "knownInputs": [
            "location",
            "facility maximum MW",
            "larger firm-design requirement",
            "design reference PUE",
            "stories",
            "project acreage",
            "historical utility scenario",
            "rack rating"
          ],
          "assumedInputs": [
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Default conditional primary tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.38396,
            "lon": -121.96575,
            "mw": 99,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": 12,
            "batteryDuration": 4,
            "loadPue": 1.25,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "SVP",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "primary",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "facility",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 99,
              "loadRackDensityKw": 10,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 4,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "fails-brief",
            "methodVersion": "2026-10-load-development-v17",
            "score": null,
            "evidenceScore": 56.8,
            "evidenceCoveragePct": 68,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": false,
              "economics": true,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "fails-brief",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "fail",
                "observed": 12,
                "required": 16.96,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "entered-scenario"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 99,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 950.4000000000003,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "facility",
              "itNameplateMw": 79.2,
              "facilityReferenceMw": 99,
              "operatingPeakMw": 89.1,
              "firmServiceRequirementMw": 99,
              "annualFacilityMwh": 780515.9999998774,
              "annualItMwh": 624412.800000138,
              "fullBuildPeakDayM3": 950.4000000000003
            },
            "utility": {
              "mapStatus": "ambiguous",
              "mappedProviders": [
                "PG&E",
                "SVP"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": "SVP",
              "selection": {
                "provider": {
                  "name": "Silicon Valley Power",
                  "acronym": "SVP",
                  "type": "POU"
                },
                "status": "conditional-user-scenario",
                "requested": "SVP",
                "explicitlySelected": true,
                "confirmed": false,
                "explanation": "The user selected this mapped utility for a conditional scenario. Other map intersections are retained; this is not confirmation of parcel service."
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 99,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "Raymond",
              "kv": 115,
              "distanceKm": 1.20492941038623,
              "demandMw": 99,
              "capacityConfirmed": false,
              "owner": "SVP",
              "ownerMatchStatus": "matching-retail-owner",
              "ownershipGate": {
                "providerAcronym": "SVP",
                "providerName": "Silicon Valley Power",
                "status": "conditional-utility-owner-match",
                "matchedCount": 31,
                "unresolvedCount": 372,
                "differentUtilityCount": 354,
                "nearbyCount": 757,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Trimble",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 3.408860064255377,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Nortech",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.118535625052517,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Signetics",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.174179713562122,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Lawrence",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.2048354371471754,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Westinghouse Tap",
                  "owner": null,
                  "kv": 115,
                  "distanceKm": 4.45343129956143,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "River Oaks",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.523916347950746,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Britton",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.592851569070381,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Applied Materials",
                  "owner": "Other",
                  "kv": 60,
                  "distanceKm": 3.666578765193001,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": 12,
              "estimatedRequiredAcres": 16.96,
              "fitRatio": 0.7075471698113207,
              "grossFloorAreaSqft": 682001.3640027279,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 79.2,
                "facilityReferenceMw": 99,
                "facilityDesignMw": 99,
                "racks": 7920,
                "whiteSpaceM2": 31680,
                "grossFloorAreaM2": 63360,
                "buildingFootprintM2": 15840,
                "hallZoneM2": 35200,
                "coolingYardM2": 9504,
                "electricalYardM2": 7920,
                "backupYardM2": 7920,
                "otherYardAcres": 2,
                "requiredAcres": 16.96074821554806,
                "acresPerMw": 0.17132068904593997,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "scenario",
              "schedule": "SVP CB-6 non-TOU",
              "annualCostUsd": 111824324.10336,
              "annualKwh": 780516000,
              "dollarsPerMwh": 143.26973963808558,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 158057215.4374,
                  "dollarsPerMwh": 202.50349184052604,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 150023107.09739998,
                  "dollarsPerMwh": 192.2101623764279,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 117848186.08425002,
                  "dollarsPerMwh": 150.98753399577973,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "SVP",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 111824324.10336,
                  "dollarsPerMwh": 143.26973963808558,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 95,
                "coverage": 100,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 94.9,
                "coverage": 55,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 72.7,
                "coverage": 85,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": 68.4,
                "coverage": 60,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": true,
            "historicalServiceKv": 60,
            "selectedMappedPoiKv": 115,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": null,
            "referenceFacilityMw": 99,
            "reportedWorstCaseFacilityMw": 99,
            "reportedExpectedDemandMw": null,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": null,
            "modeledVsReportedGrossFloorAreaRatio": 1.0850495176196542,
            "modeledRequiredVsReportedCampusAcresRatio": 1.4133333333333333,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        }
      },
      "assertions": [
        {
          "id": "historical-utility-retained",
          "pass": true,
          "detail": "Named historical provider is present among map candidates; other genuine overlaps are retained. A failure needs a coordinate/territory review, not forced provider substitution."
        },
        {
          "id": "conditional-provider-only",
          "pass": true,
          "detail": "Explicit historical provider scenario can price a bill while parcel service stays unconfirmed."
        },
        {
          "id": "no-historical-service-reservation",
          "pass": true,
          "detail": "Historical campus power and age never populate current service capacity or energization commitments."
        },
        {
          "id": "bulk-pathway",
          "pass": true,
          "detail": "These documented96–99.8MW campuses need dedicated-service investigation; distribution forecasts do not establish their readiness."
        },
        {
          "id": "firm-demand-preserved",
          "pass": true,
          "detail": "A90% operating-load assumption must not shrink full-build service demand."
        },
        {
          "id": "mva-not-converted",
          "pass": true,
          "detail": "ServiceMVA is reference context, never the modelMW input."
        },
        {
          "id": "tariff-is-conditional",
          "pass": true,
          "detail": "Published-rate annual costs remain conditional2026 scenarios, not historical or future bills."
        },
        {
          "id": "no-cheapest-provider-selection",
          "pass": true,
          "detail": "Named historical provider is used explicitly; no cheapest overlapping provider is inferred."
        },
        {
          "id": "poi-not-capacity",
          "pass": true,
          "detail": "MappedkV and station proximity do not confirm spareMW or historical circuit diversity."
        },
        {
          "id": "poi-respects-conditional-utility",
          "pass": true,
          "detail": "A preferred mapped station must match the named conditional retail utility; unknown, joint and different-owner stations remain unresolved nearby context."
        },
        {
          "id": "map-owner-not-current-service",
          "pass": true,
          "detail": "Reviewed inventory ownership is not current ownership confirmation or parcel retail service eligibility."
        }
      ],
      "interpretation": "The stated PUE is an applicant design expectation. Facility 99 MW at peak ambient conditions is not a measured annual draw; inferred IT 79.2 MW under constant PUE 1.25 is only a validator scenario. The four-story industrial redevelopment illustrates why a universal acres/MW assumption cannot reject a real campus."
    },
    {
      "id": "cec:21-SPPE-01",
      "name": "Vantage CA3 Data Center",
      "location": {
        "lat": 37.370735,
        "lon": -121.97451,
        "quality": "published-map-point-unverified",
        "basis": "Previously bundled Cleanview record 4138; matched by project name/address context. Coordinate precision is not accuracy.",
        "sourceId": "ca3-map-point"
      },
      "reported": {
        "itNameplateMw": 64,
        "facilityMaximumMw": 96,
        "expectedFacilityDemandMw": 77,
        "referencePue": 1.26,
        "rackDensityKw": null,
        "serviceMva": 100,
        "installedTransformerMva": null,
        "serviceKv": 60,
        "utilityAcronym": "SVP",
        "siteAcres": 6.69,
        "siteAcresBasis": "Proposed project site in the 2022 notice",
        "buildingStories": 4,
        "grossBuildingFloorSqft": 468000,
        "buildingCount": 1,
        "backupGeneratorCount": 44,
        "backupGeneratorNameplateMwEach": 2.75,
        "backupArchitecture": "Forty data-suite generators with eight redundant plus four house generators with two redundant; grouped five-to-make-four. Adjacent SVP Uranium station and new60 kV switching station.",
        "utilityCircuitCount": null,
        "currentSpareServiceMw": null,
        "currentCommittedServiceYear": null
      },
      "sources": [
        {
          "id": "ca3-revised",
          "title": "Applicant revised project description, TN240159",
          "date": "2021-10-28",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=73611&tn=240159",
          "pages": "PDF2/4-5; printed2-1/2-3/2-4",
          "supports": [
            "itNameplateMw",
            "facilityMaximumMw",
            "expectedFacilityDemandMw",
            "referencePue",
            "backupGeneratorCount",
            "backupGeneratorNameplateMwEach",
            "backupArchitecture"
          ]
        },
        {
          "id": "ca3-notice",
          "title": "CEC Notice of Determination, TN245041",
          "date": "2022-08-12",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=79168&tn=245041",
          "pages": "PDF3; AttachmentA",
          "supports": [
            "siteAcres",
            "buildingStories",
            "grossBuildingFloorSqft",
            "buildingCount",
            "serviceMva",
            "serviceKv",
            "utilityAcronym"
          ]
        },
        {
          "id": "ca3-map-point",
          "title": "Bundled Cleanview map record 4138, coordinates only",
          "date": "2026-09-14",
          "url": "https://cleanview.co/data-centers/california/4138/vantage-ca3",
          "pages": null,
          "supports": [
            "location"
          ]
        }
      ],
      "variants": {
        "genericArchitecture": {
          "scope": "Same MW and PUE with generic architecture / automatic map utility",
          "knownInputs": [
            "location",
            "IT nameplate MW",
            "larger firm-design requirement",
            "design reference PUE"
          ],
          "assumedInputs": [
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Default conditional primary tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.37074,
            "lon": -121.97451,
            "mw": 64,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": null,
            "batteryDuration": 4,
            "loadPue": 1.26,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "primary",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "it",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 96,
              "loadRackDensityKw": 30,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 2,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "insufficient-data",
            "methodVersion": "2026-10-load-development-v17",
            "score": null,
            "evidenceScore": 21,
            "evidenceCoveragePct": 27.3,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": true,
              "economics": false,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "requires-confirmation",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "unknown",
                "observed": null,
                "required": 12.38,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 96,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 768,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "it",
              "itNameplateMw": 64,
              "facilityReferenceMw": 80.64,
              "operatingPeakMw": 72.57600000000001,
              "firmServiceRequirementMw": 96,
              "annualFacilityMwh": 635765.7600000078,
              "annualItMwh": 504575.9999999207,
              "fullBuildPeakDayM3": 768
            },
            "utility": {
              "mapStatus": "ambiguous",
              "mappedProviders": [
                "PG&E",
                "SVP"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": null,
              "selection": {
                "provider": null,
                "status": "ambiguous",
                "requested": null,
                "explicitlySelected": false,
                "confirmed": false
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 96,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "No utility-matched preferred POI",
              "kv": null,
              "distanceKm": null,
              "demandMw": 96,
              "capacityConfirmed": false,
              "owner": null,
              "ownerMatchStatus": null,
              "ownershipGate": {
                "providerAcronym": null,
                "providerName": null,
                "status": "utility-unresolved",
                "matchedCount": 0,
                "unresolvedCount": 367,
                "differentUtilityCount": 0,
                "nearbyCount": 748,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Unknown",
                  "owner": "SVP",
                  "kv": 66,
                  "distanceKm": 0.4926096736391737,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Uranium",
                  "owner": "SVP",
                  "kv": 60,
                  "distanceKm": 0.15925187511622807,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Northwestern",
                  "owner": "SVP",
                  "kv": 60,
                  "distanceKm": 0.36318832106201054,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Raymond",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.8343515814195033,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Kenneth",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.8702455951609516,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Scott",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 1.928984214957019,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Fiberglas",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 2.1104729189626785,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Duane",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 2.1525134179272976,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": null,
              "estimatedRequiredAcres": 12.38,
              "fitRatio": null,
              "grossFloorAreaSqft": 183761.47863406836,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 64,
                "facilityReferenceMw": 80.64,
                "facilityDesignMw": 96,
                "racks": 2134,
                "whiteSpaceM2": 8536,
                "grossFloorAreaM2": 17072,
                "buildingFootprintM2": 8536,
                "hallZoneM2": 18968.888888888887,
                "coolingYardM2": 7680,
                "electricalYardM2": 7680,
                "backupYardM2": 7680,
                "otherYardAcres": 2,
                "requiredAcres": 12.380622513900652,
                "acresPerMw": 0.1934472267796977,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "unresolved",
              "schedule": null,
              "annualCostUsd": null,
              "annualKwh": null,
              "dollarsPerMwh": null,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 128752054.11916001,
                  "dollarsPerMwh": 202.5149232936986,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 122208108.18996005,
                  "dollarsPerMwh": 192.22190919806695,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 96015168.64305001,
                  "dollarsPerMwh": 151.022868301448,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "SVP",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 91746951.32740083,
                  "dollarsPerMwh": 144.30936218930825,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "project-land",
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 99.7,
                "coverage": 5,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 95.5,
                "coverage": 55,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 61.9,
                "coverage": 75,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": null,
                "coverage": 0,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": false,
            "historicalServiceKv": 60,
            "selectedMappedPoiKv": null,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": 0,
            "referenceFacilityMw": 80.64,
            "reportedWorstCaseFacilityMw": 96,
            "reportedExpectedDemandMw": 77,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": 100,
            "modeledVsReportedGrossFloorAreaRatio": 0.3926527321240777,
            "modeledRequiredVsReportedCampusAcresRatio": 1.850523168908819,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        },
        "documentedBrief": {
          "scope": "Source-informed historical design scenario",
          "knownInputs": [
            "location",
            "IT nameplate MW",
            "larger firm-design requirement",
            "design reference PUE",
            "stories",
            "project acreage",
            "historical utility scenario"
          ],
          "assumedInputs": [
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Default conditional primary tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.37074,
            "lon": -121.97451,
            "mw": 64,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": 6.69,
            "batteryDuration": 4,
            "loadPue": 1.26,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "SVP",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "primary",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "it",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 96,
              "loadRackDensityKw": 30,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 4,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "fails-brief",
            "methodVersion": "2026-10-load-development-v17",
            "score": null,
            "evidenceScore": 54.9,
            "evidenceCoveragePct": 70,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": false,
              "economics": true,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "fails-brief",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "fail",
                "observed": 6.69,
                "required": 10.04,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "entered-scenario"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 96,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 768,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "it",
              "itNameplateMw": 64,
              "facilityReferenceMw": 80.64,
              "operatingPeakMw": 72.57600000000001,
              "firmServiceRequirementMw": 96,
              "annualFacilityMwh": 635765.7600000078,
              "annualItMwh": 504575.9999999207,
              "fullBuildPeakDayM3": 768
            },
            "utility": {
              "mapStatus": "ambiguous",
              "mappedProviders": [
                "PG&E",
                "SVP"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": "SVP",
              "selection": {
                "provider": {
                  "name": "Silicon Valley Power",
                  "acronym": "SVP",
                  "type": "POU"
                },
                "status": "conditional-user-scenario",
                "requested": "SVP",
                "explicitlySelected": true,
                "confirmed": false,
                "explanation": "The user selected this mapped utility for a conditional scenario. Other map intersections are retained; this is not confirmation of parcel service."
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 96,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "Unknown",
              "kv": 66,
              "distanceKm": 0.4926096736391737,
              "demandMw": 96,
              "capacityConfirmed": false,
              "owner": "SVP",
              "ownerMatchStatus": "matching-retail-owner",
              "ownershipGate": {
                "providerAcronym": "SVP",
                "providerName": "Silicon Valley Power",
                "status": "conditional-utility-owner-match",
                "matchedCount": 31,
                "unresolvedCount": 367,
                "differentUtilityCount": 350,
                "nearbyCount": 748,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Britton",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 3.723026707323836,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Westinghouse Tap",
                  "owner": null,
                  "kv": 115,
                  "distanceKm": 3.7305317876130917,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Signetics",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 3.74766414701933,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Applied Materials",
                  "owner": "Other",
                  "kv": 60,
                  "distanceKm": 2.9036975231193094,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Lawrence",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.321642585922572,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Trimble",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.362295202031314,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Advanced Micro Devices",
                  "owner": "Other",
                  "kv": 60,
                  "distanceKm": 3.508984735601673,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "FMC",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 5.326868678517328,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": 6.69,
              "estimatedRequiredAcres": 10.04,
              "fitRatio": 0.6663346613545817,
              "grossFloorAreaSqft": 183761.47863406836,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 64,
                "facilityReferenceMw": 80.64,
                "facilityDesignMw": 96,
                "racks": 2134,
                "whiteSpaceM2": 8536,
                "grossFloorAreaM2": 17072,
                "buildingFootprintM2": 4268,
                "hallZoneM2": 9484.444444444443,
                "coolingYardM2": 7680,
                "electricalYardM2": 7680,
                "backupYardM2": 7680,
                "otherYardAcres": 2,
                "requiredAcres": 10.03696525145207,
                "acresPerMw": 0.1568275820539386,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "scenario",
              "schedule": "SVP CB-6 non-TOU",
              "annualCostUsd": 91746951.32740083,
              "annualKwh": 635765760.0000001,
              "dollarsPerMwh": 144.30936218930825,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 128752054.11916001,
                  "dollarsPerMwh": 202.5149232936986,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 122208108.18996005,
                  "dollarsPerMwh": 192.22190919806695,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 96015168.64305001,
                  "dollarsPerMwh": 151.022868301448,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "SVP",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 91746951.32740083,
                  "dollarsPerMwh": 144.30936218930825,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 94.9,
                "coverage": 100,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 95.5,
                "coverage": 55,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 55.5,
                "coverage": 95,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": 67.8,
                "coverage": 60,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": true,
            "historicalServiceKv": 60,
            "selectedMappedPoiKv": 66,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": 0,
            "referenceFacilityMw": 80.64,
            "reportedWorstCaseFacilityMw": 96,
            "reportedExpectedDemandMw": 77,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": 100,
            "modeledVsReportedGrossFloorAreaRatio": 0.3926527321240777,
            "modeledRequiredVsReportedCampusAcresRatio": 1.5007473841554557,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        }
      },
      "assertions": [
        {
          "id": "historical-utility-retained",
          "pass": true,
          "detail": "Named historical provider is present among map candidates; other genuine overlaps are retained. A failure needs a coordinate/territory review, not forced provider substitution."
        },
        {
          "id": "conditional-provider-only",
          "pass": true,
          "detail": "Explicit historical provider scenario can price a bill while parcel service stays unconfirmed."
        },
        {
          "id": "no-historical-service-reservation",
          "pass": true,
          "detail": "Historical campus power and age never populate current service capacity or energization commitments."
        },
        {
          "id": "bulk-pathway",
          "pass": true,
          "detail": "These documented96–99.8MW campuses need dedicated-service investigation; distribution forecasts do not establish their readiness."
        },
        {
          "id": "firm-demand-preserved",
          "pass": true,
          "detail": "A90% operating-load assumption must not shrink full-build service demand."
        },
        {
          "id": "it-nameplate-preserved",
          "pass": true,
          "detail": "ReportedITMW is distinct from facilityMW and referencePUE overhead."
        },
        {
          "id": "mva-not-converted",
          "pass": true,
          "detail": "ServiceMVA is reference context, never the modelMW input."
        },
        {
          "id": "tariff-is-conditional",
          "pass": true,
          "detail": "Published-rate annual costs remain conditional2026 scenarios, not historical or future bills."
        },
        {
          "id": "no-cheapest-provider-selection",
          "pass": true,
          "detail": "Named historical provider is used explicitly; no cheapest overlapping provider is inferred."
        },
        {
          "id": "poi-not-capacity",
          "pass": true,
          "detail": "MappedkV and station proximity do not confirm spareMW or historical circuit diversity."
        },
        {
          "id": "poi-respects-conditional-utility",
          "pass": true,
          "detail": "A preferred mapped station must match the named conditional retail utility; unknown, joint and different-owner stations remain unresolved nearby context."
        },
        {
          "id": "map-owner-not-current-service",
          "pass": true,
          "detail": "Reviewed inventory ownership is not current ownership confirmation or parcel retail service eligibility."
        }
      ],
      "interpretation": "Source96 MW worst-case service demand remains distinct from64 MW IT,100 MVA equipment and77 MW expected leased demand. Reference PUE 1.26 gives80.64 MW at fullIT; the stated96 MW maximum is a separate firm-design requirement. Its six-decimal map point is unverified."
    },
    {
      "id": "cec:19-SPPE-04",
      "name": "Microsoft San Jose Data Center",
      "location": {
        "lat": 37.4210432,
        "lon": -121.9314939,
        "quality": "published-map-point-unverified",
        "basis": "Previously bundled Cleanview Alviso-Milpitas campus record 926; corresponding address and Microsoft developer in CEC docket. Not a validated parcel centroid.",
        "sourceId": "san-jose-map-point"
      },
      "reported": {
        "itNameplateMw": null,
        "facilityMaximumMw": 99,
        "expectedFacilityDemandMw": 77,
        "referencePue": null,
        "rackDensityKw": null,
        "serviceMva": null,
        "installedTransformerMva": null,
        "serviceKv": 115,
        "utilityAcronym": "PG&E",
        "siteAcres": 64.5,
        "siteAcresBasis": "Project site described in the 2022 DEIR",
        "buildingStories": 1,
        "grossBuildingFloorSqft": 396914,
        "buildingCount": 2,
        "backupGeneratorCount": 224,
        "backupGeneratorNameplateMwEach": 0.45,
        "backupArchitecture": "224 natural-gas generator packages plus separate1.25 MW / 0.5 MW administrative diesel generators; two115 kV underground supply lines to PG&E Los Esteros. Two circuits do not prove physically independent upstream sources.",
        "utilityCircuitCount": 2,
        "currentSpareServiceMw": null,
        "currentCommittedServiceYear": null
      },
      "sources": [
        {
          "id": "san-jose-notice",
          "title": "CEC Notice of Determination, TN244110",
          "date": "2022-07-18",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=78002&tn=244110",
          "pages": "PDF3; AttachmentA",
          "supports": [
            "facilityMaximumMw",
            "expectedFacilityDemandMw",
            "buildingStories",
            "grossBuildingFloorSqft",
            "buildingCount",
            "serviceKv",
            "utilityAcronym",
            "backupGeneratorCount",
            "backupGeneratorNameplateMwEach",
            "utilityCircuitCount",
            "backupArchitecture"
          ]
        },
        {
          "id": "san-jose-deir",
          "title": "CEC San Jose Data Center Draft EIR, TN241076",
          "date": "2022-01",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=74907&tn=241076",
          "pages": "printed3-2/3-5",
          "supports": [
            "siteAcres"
          ]
        },
        {
          "id": "san-jose-map-point",
          "title": "Bundled Cleanview map record 926, coordinates only",
          "date": "2026-09-14",
          "url": "https://cleanview.co/data-centers/california/926/alviso-milpitas-san-jose-campus",
          "pages": null,
          "supports": [
            "location"
          ]
        }
      ],
      "variants": {
        "genericArchitecture": {
          "scope": "Same MW and PUE with generic architecture / automatic map utility",
          "knownInputs": [
            "location",
            "facility maximum MW",
            "larger firm-design requirement"
          ],
          "assumedInputs": [
            "PUE1.25; actual PUE unreported",
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Default conditional primary tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.42104,
            "lon": -121.93149,
            "mw": 99,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": null,
            "batteryDuration": 4,
            "loadPue": 1.25,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "primary",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "facility",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 99,
              "loadRackDensityKw": 30,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 2,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "provisional",
            "methodVersion": "2026-10-load-development-v17",
            "score": 45.5,
            "evidenceScore": 45.5,
            "evidenceCoveragePct": 60,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": true,
              "economics": true,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "requires-confirmation",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "unknown",
                "observed": null,
                "required": 14.06,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 99,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 950.4000000000003,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "facility",
              "itNameplateMw": 79.2,
              "facilityReferenceMw": 99,
              "operatingPeakMw": 89.1,
              "firmServiceRequirementMw": 99,
              "annualFacilityMwh": 780515.9999998774,
              "annualItMwh": 624412.800000138,
              "fullBuildPeakDayM3": 950.4000000000003
            },
            "utility": {
              "mapStatus": "mapped",
              "mappedProviders": [
                "PG&E"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": "PG&E",
              "selection": {
                "provider": {
                  "name": "Pacific Gas & Electric Company",
                  "acronym": "PG&E",
                  "type": "IOU"
                },
                "status": "unique-map-match",
                "requested": null,
                "explicitlySelected": false,
                "confirmed": false
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 99,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "River Oaks",
              "kv": 115,
              "distanceKm": 1.1478212515602417,
              "demandMw": 99,
              "capacityConfirmed": false,
              "owner": "PG&E",
              "ownerMatchStatus": "matching-retail-owner",
              "ownershipGate": {
                "providerAcronym": "PG&E",
                "providerName": "Pacific Gas & Electric Company",
                "status": "conditional-utility-owner-match",
                "matchedCount": 363,
                "unresolvedCount": 388,
                "differentUtilityCount": 31,
                "nearbyCount": 782,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Svp",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.5568468503054418,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Road",
                  "owner": "Other",
                  "kv": 115,
                  "distanceKm": 2.0293963585825536,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Unknown",
                  "owner": null,
                  "kv": 66,
                  "distanceKm": 2.00795727387636,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Wpcp",
                  "owner": "Other",
                  "kv": 60,
                  "distanceKm": 1.5954651332952072,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Unknown",
                  "owner": null,
                  "kv": 66,
                  "distanceKm": 2.763940158101785,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Northern Receiving Station",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 3.7502813354937667,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Unknown",
                  "owner": null,
                  "kv": 66,
                  "distanceKm": 3.02017231159736,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Tasman",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 4.178500113041817,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": null,
              "estimatedRequiredAcres": 14.06,
              "fitRatio": null,
              "grossFloorAreaSqft": 227333.78800090932,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 79.2,
                "facilityReferenceMw": 99,
                "facilityDesignMw": 99,
                "racks": 2640,
                "whiteSpaceM2": 10560,
                "grossFloorAreaM2": 21120,
                "buildingFootprintM2": 10560,
                "hallZoneM2": 23466.666666666668,
                "coolingYardM2": 9504,
                "electricalYardM2": 7920,
                "backupYardM2": 7920,
                "otherYardAcres": 2,
                "requiredAcres": 14.061378406333318,
                "acresPerMw": 0.14203412531649817,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "scenario",
              "schedule": "PG&E B-20 bundled TOU",
              "annualCostUsd": 150023107.09739998,
              "annualKwh": 780516000,
              "dollarsPerMwh": 192.2101623764279,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 158057215.4374,
                  "dollarsPerMwh": 202.50349184052604,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 150023107.09739998,
                  "dollarsPerMwh": 192.2101623764279,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 117848186.08425002,
                  "dollarsPerMwh": 150.98753399577973,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "project-land",
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 95.3,
                "coverage": 100,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 87.7,
                "coverage": 35,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 68.7,
                "coverage": 65,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": 43.9,
                "coverage": 60,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": true,
            "historicalServiceKv": 115,
            "selectedMappedPoiKv": 115,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": null,
            "referenceFacilityMw": 99,
            "reportedWorstCaseFacilityMw": 99,
            "reportedExpectedDemandMw": 77,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": null,
            "modeledVsReportedGrossFloorAreaRatio": 0.572753261414083,
            "modeledRequiredVsReportedCampusAcresRatio": 0.217984496124031,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        },
        "documentedBrief": {
          "scope": "Source-informed historical design scenario",
          "knownInputs": [
            "location",
            "facility maximum MW",
            "larger firm-design requirement",
            "stories",
            "project acreage",
            "historical utility scenario"
          ],
          "assumedInputs": [
            "PUE1.25; actual PUE unreported",
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Conditional high-voltage tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.42104,
            "lon": -121.93149,
            "mw": 99,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": 64.5,
            "batteryDuration": 4,
            "loadPue": 1.25,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "PG&E",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "transmission",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "facility",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 99,
              "loadRackDensityKw": 30,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 1,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "provisional",
            "methodVersion": "2026-10-load-development-v17",
            "score": 52.6,
            "evidenceScore": 52.6,
            "evidenceCoveragePct": 64,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": true,
              "economics": true,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "requires-confirmation",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "pass",
                "observed": 64.5,
                "required": 19.86,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "entered-scenario"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 99,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 950.4000000000003,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "facility",
              "itNameplateMw": 79.2,
              "facilityReferenceMw": 99,
              "operatingPeakMw": 89.1,
              "firmServiceRequirementMw": 99,
              "annualFacilityMwh": 780515.9999998774,
              "annualItMwh": 624412.800000138,
              "fullBuildPeakDayM3": 950.4000000000003
            },
            "utility": {
              "mapStatus": "mapped",
              "mappedProviders": [
                "PG&E"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": "PG&E",
              "selection": {
                "provider": {
                  "name": "Pacific Gas & Electric Company",
                  "acronym": "PG&E",
                  "type": "IOU"
                },
                "status": "conditional-user-scenario",
                "requested": "PG&E",
                "explicitlySelected": true,
                "confirmed": false,
                "explanation": "The user selected this mapped utility for a conditional scenario. Other map intersections are retained; this is not confirmation of parcel service."
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 99,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "River Oaks",
              "kv": 115,
              "distanceKm": 1.1478212515602417,
              "demandMw": 99,
              "capacityConfirmed": false,
              "owner": "PG&E",
              "ownerMatchStatus": "matching-retail-owner",
              "ownershipGate": {
                "providerAcronym": "PG&E",
                "providerName": "Pacific Gas & Electric Company",
                "status": "conditional-utility-owner-match",
                "matchedCount": 363,
                "unresolvedCount": 388,
                "differentUtilityCount": 31,
                "nearbyCount": 782,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Svp",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.5568468503054418,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Road",
                  "owner": "Other",
                  "kv": 115,
                  "distanceKm": 2.0293963585825536,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Unknown",
                  "owner": null,
                  "kv": 66,
                  "distanceKm": 2.00795727387636,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Wpcp",
                  "owner": "Other",
                  "kv": 60,
                  "distanceKm": 1.5954651332952072,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Unknown",
                  "owner": null,
                  "kv": 66,
                  "distanceKm": 2.763940158101785,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Northern Receiving Station",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 3.7502813354937667,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Unknown",
                  "owner": null,
                  "kv": 66,
                  "distanceKm": 3.02017231159736,
                  "ownerMatchStatus": "ownership-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Tasman",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 4.178500113041817,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": 64.5,
              "estimatedRequiredAcres": 19.86,
              "fitRatio": 3.2477341389728096,
              "grossFloorAreaSqft": 227333.78800090932,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 79.2,
                "facilityReferenceMw": 99,
                "facilityDesignMw": 99,
                "racks": 2640,
                "whiteSpaceM2": 10560,
                "grossFloorAreaM2": 21120,
                "buildingFootprintM2": 21120,
                "hallZoneM2": 46933.333333333336,
                "coolingYardM2": 9504,
                "electricalYardM2": 7920,
                "backupYardM2": 7920,
                "otherYardAcres": 2,
                "requiredAcres": 19.8601180247628,
                "acresPerMw": 0.20060725277538183,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "scenario",
              "schedule": "PG&E B-20 bundled TOU",
              "annualCostUsd": 117848186.08425002,
              "annualKwh": 780516000,
              "dollarsPerMwh": 150.98753399577973,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 158057215.4374,
                  "dollarsPerMwh": 202.50349184052604,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 150023107.09739998,
                  "dollarsPerMwh": 192.2101623764279,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 117848186.08425002,
                  "dollarsPerMwh": 150.98753399577973,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 95.3,
                "coverage": 100,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 87.7,
                "coverage": 35,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 76.1,
                "coverage": 85,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": 64.5,
                "coverage": 60,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": true,
            "historicalServiceKv": 115,
            "selectedMappedPoiKv": 115,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": null,
            "referenceFacilityMw": 99,
            "reportedWorstCaseFacilityMw": 99,
            "reportedExpectedDemandMw": 77,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": null,
            "modeledVsReportedGrossFloorAreaRatio": 0.572753261414083,
            "modeledRequiredVsReportedCampusAcresRatio": 0.30790697674418605,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        }
      },
      "assertions": [
        {
          "id": "historical-utility-retained",
          "pass": true,
          "detail": "Named historical provider is present among map candidates; other genuine overlaps are retained. A failure needs a coordinate/territory review, not forced provider substitution."
        },
        {
          "id": "conditional-provider-only",
          "pass": true,
          "detail": "Explicit historical provider scenario can price a bill while parcel service stays unconfirmed."
        },
        {
          "id": "no-historical-service-reservation",
          "pass": true,
          "detail": "Historical campus power and age never populate current service capacity or energization commitments."
        },
        {
          "id": "bulk-pathway",
          "pass": true,
          "detail": "These documented96–99.8MW campuses need dedicated-service investigation; distribution forecasts do not establish their readiness."
        },
        {
          "id": "firm-demand-preserved",
          "pass": true,
          "detail": "A90% operating-load assumption must not shrink full-build service demand."
        },
        {
          "id": "mva-not-converted",
          "pass": true,
          "detail": "ServiceMVA is reference context, never the modelMW input."
        },
        {
          "id": "tariff-is-conditional",
          "pass": true,
          "detail": "Published-rate annual costs remain conditional2026 scenarios, not historical or future bills."
        },
        {
          "id": "no-cheapest-provider-selection",
          "pass": true,
          "detail": "Named historical provider is used explicitly; no cheapest overlapping provider is inferred."
        },
        {
          "id": "poi-not-capacity",
          "pass": true,
          "detail": "MappedkV and station proximity do not confirm spareMW or historical circuit diversity."
        },
        {
          "id": "poi-respects-conditional-utility",
          "pass": true,
          "detail": "A preferred mapped station must match the named conditional retail utility; unknown, joint and different-owner stations remain unresolved nearby context."
        },
        {
          "id": "map-owner-not-current-service",
          "pass": true,
          "detail": "Reviewed inventory ownership is not current ownership confirmation or parcel retail service eligibility."
        }
      ],
      "interpretation": "Facility 99 MW maximum and77 MW estimated load includeIT, cooling and ancillary demand. Neither is a confirmed annual operating profile. Its64.5-acre single-story campus and115 kV architecture differ from dense Santa Clara campuses. Historical plans do not reserve capacity for another applicant."
    },
    {
      "id": "cec:20-SPPE-02",
      "name": "Lafayette Data Center",
      "location": {
        "lat": 37.373058,
        "lon": -121.947714,
        "quality": "docket-target-property-point-not-validated-parcel-centroid",
        "basis": "Target 2845 Lafayette property coordinates in applicant environmental site-assessment appendix; the expanded campus also uses part of the neighboring parcel.",
        "sourceId": "lafayette-location"
      },
      "reported": {
        "itNameplateMw": 66,
        "facilityMaximumMw": 99.8,
        "expectedFacilityDemandMw": 60,
        "referencePue": 1.42,
        "rackDensityKw": null,
        "serviceMva": 100,
        "installedTransformerMva": 150,
        "serviceKv": 60,
        "utilityAcronym": "SVP",
        "siteAcres": 15.45,
        "originalParcelAcres": 13.04,
        "siteAcresBasis": "Expanded15.45-acre project parcel after proposed lot-line adjustment;13.04 acres describes original northern parcel",
        "buildingStories": 3,
        "grossBuildingFloorSqft": 575401,
        "buildingCount": 1,
        "backupGeneratorCount": 45,
        "backupGeneratorNameplateMwEach": null,
        "backupArchitecture": "Eleven four-to-make-three suite groups plus administrative generator; three 50 MVA 60/12 kV transformers, two needed. Part of building reduces to two floors for airport proximity.",
        "utilityCircuitCount": null,
        "currentSpareServiceMw": null,
        "currentCommittedServiceYear": null
      },
      "sources": [
        {
          "id": "lafayette-revised",
          "title": "Applicant revised project description, TN248686",
          "date": "2023-02-07",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=83199&tn=248686",
          "pages": "PDF2/4/11; printed1/3/10; architectural plan575401ft²",
          "supports": [
            "itNameplateMw",
            "facilityMaximumMw",
            "expectedFacilityDemandMw",
            "referencePue",
            "serviceMva",
            "installedTransformerMva",
            "serviceKv",
            "utilityAcronym",
            "siteAcres",
            "originalParcelAcres",
            "buildingStories",
            "grossBuildingFloorSqft",
            "buildingCount",
            "backupGeneratorCount",
            "backupArchitecture"
          ]
        },
        {
          "id": "lafayette-location",
          "title": "Applicant SPPE environmental site-assessment appendix, TN233041-3",
          "date": "2020-05",
          "url": "https://efiling.energy.ca.gov/GetDocument.aspx?DocumentContentId=65521&tn=233041-3",
          "pages": "EDRExecutiveSummary1; targetpropertycoordinates",
          "supports": [
            "location"
          ]
        }
      ],
      "variants": {
        "genericArchitecture": {
          "scope": "Same MW and PUE with generic architecture / automatic map utility",
          "knownInputs": [
            "location",
            "IT nameplate MW",
            "larger firm-design requirement",
            "design reference PUE"
          ],
          "assumedInputs": [
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Default conditional primary tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.37306,
            "lon": -121.94771,
            "mw": 66,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": null,
            "batteryDuration": 4,
            "loadPue": 1.42,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "primary",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "it",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 99.8,
              "loadRackDensityKw": 30,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 2,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "insufficient-data",
            "methodVersion": "2026-10-load-development-v17",
            "score": null,
            "evidenceScore": 22.7,
            "evidenceCoveragePct": 27.3,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": true,
              "economics": false,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "requires-confirmation",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "unknown",
                "observed": null,
                "required": 12.74,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 99.8,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 792,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "it",
              "itNameplateMw": 66,
              "facilityReferenceMw": 93.72,
              "operatingPeakMw": 84.348,
              "firmServiceRequirementMw": 99.8,
              "annualFacilityMwh": 738888.4800000705,
              "annualItMwh": 520344.00000008306,
              "fullBuildPeakDayM3": 792
            },
            "utility": {
              "mapStatus": "ambiguous",
              "mappedProviders": [
                "PG&E",
                "SVP"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": null,
              "selection": {
                "provider": null,
                "status": "ambiguous",
                "requested": null,
                "explicitlySelected": false,
                "confirmed": false
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 99.8,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "No utility-matched preferred POI",
              "kv": null,
              "distanceKm": null,
              "demandMw": 99.8,
              "capacityConfirmed": false,
              "owner": null,
              "ownerMatchStatus": null,
              "ownershipGate": {
                "providerAcronym": null,
                "providerName": null,
                "status": "utility-unresolved",
                "matchedCount": 0,
                "unresolvedCount": 375,
                "differentUtilityCount": 0,
                "nearbyCount": 757,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Fiberglas",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.2887751588456137,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Lafayette",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.42920796851711895,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Kifer",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.4764710626425998,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Container Corp.",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.49349625259756885,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Don Van Raesfeld",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.4944418121389138,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Duane",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.5445845535105575,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Kenneth",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.6594592879574629,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                },
                {
                  "name": "Scott",
                  "owner": "SVP",
                  "kv": 115,
                  "distanceKm": 0.7278076366707725,
                  "ownerMatchStatus": "utility-unresolved",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": null,
              "estimatedRequiredAcres": 12.74,
              "fitRatio": null,
              "grossFloorAreaSqft": 189444.8233340911,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 66,
                "facilityReferenceMw": 93.72,
                "facilityDesignMw": 99.8,
                "racks": 2200,
                "whiteSpaceM2": 8800,
                "grossFloorAreaM2": 17600,
                "buildingFootprintM2": 8800,
                "hallZoneM2": 19555.555555555555,
                "coolingYardM2": 7920,
                "electricalYardM2": 7984,
                "backupYardM2": 7984,
                "otherYardAcres": 2,
                "requiredAcres": 12.735136367845545,
                "acresPerMw": 0.19295661163402342,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "unresolved",
              "schedule": null,
              "annualCostUsd": null,
              "annualKwh": null,
              "dollarsPerMwh": null,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 149629587.34588003,
                  "dollarsPerMwh": 202.50632050168116,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 142024022.44428,
                  "dollarsPerMwh": 192.21306907407734,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 111569409.82665,
                  "dollarsPerMwh": 150.99627730919556,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "SVP",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 106050439.1220384,
                  "dollarsPerMwh": 143.52698951543866,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "project-land",
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 99.3,
                "coverage": 5,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 92.2,
                "coverage": 55,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 75.2,
                "coverage": 75,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": null,
                "coverage": 0,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": false,
            "historicalServiceKv": 60,
            "selectedMappedPoiKv": null,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": 0,
            "referenceFacilityMw": 93.72,
            "reportedWorstCaseFacilityMw": 99.8,
            "reportedExpectedDemandMw": 60,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": 100,
            "modeledVsReportedGrossFloorAreaRatio": 0.3292396491040007,
            "modeledRequiredVsReportedCampusAcresRatio": 0.8245954692556635,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        },
        "documentedBrief": {
          "scope": "Source-informed historical design scenario",
          "knownInputs": [
            "location",
            "IT nameplate MW",
            "larger firm-design requirement",
            "design reference PUE",
            "stories",
            "project acreage",
            "historical utility scenario"
          ],
          "assumedInputs": [
            "Constant PUE reference model; no vendor cooling calibration",
            "90% flat annual utilization; not inferred from expected demand",
            "Default WUE and unreported rack/space/yard coefficients",
            "Default conditional primary tariff class; actual contract unverified"
          ],
          "withheld": [
            "Current spare service capacity",
            "Current energization commitment",
            "Supplier water allocation",
            "Independent commercial fiber routes",
            "Post-contingency generator power and usable fuel"
          ],
          "input": {
            "type": "load",
            "lat": 37.37306,
            "lon": -121.94771,
            "mw": 66,
            "year": 2030,
            "minKv": 34.5,
            "radiusKm": 25,
            "acresPerMw": 0.5,
            "siteAreaAcres": 15.45,
            "batteryDuration": 4,
            "loadPue": 1.42,
            "loadWue": 0.5,
            "loadFactor": 0.9,
            "loadProfile": "steady",
            "solarDcAcRatio": 1.3,
            "customUse": null,
            "footprint": null,
            "loadConnectionLevel": "auto",
            "loadServingUtility": "SVP",
            "weights": {
              "grid": 25,
              "resource": 20,
              "development": 20,
              "market": 25,
              "queue": 10
            },
            "hourlyLoadShape": null,
            "liveEvidence": [],
            "loadServiceVoltage": "primary",
            "design": {
              "customProcess": "",
              "developmentPathway": "greenfield",
              "batteryRequiredImportMw": null,
              "batteryRequiredExportMw": null,
              "loadRequiredFiberRoutes": null,
              "h2SolarSiteAreaAcres": null,
              "h2WindSiteAreaAcres": null,
              "h2MaxShortageHours": null,
              "h2MinFullyServedHoursPct": null,
              "batteryCommercialMode": "merchant",
              "batteryCostMode": "components",
              "batteryCostVintage": 2026,
              "batteryCapitalTrajectory": "constant",
              "batteryEnergyCapexPerKwh": 200,
              "batteryPowerCapexPerKw": 600,
              "batteryAuxiliaryPct": 0,
              "batteryThermalMode": "constant",
              "batteryThermalThresholdC": 35,
              "batteryThermalDeratePctPerC": 1,
              "batteryThermalAuxPctPerC": 0.05,
              "batteryOutageStartDay": 1,
              "batteryOutageDays": 0,
              "batteryPriceKnowledge": "previous-day",
              "batteryDispatchWindow": "daily",
              "batteryReserveParticipationPct": 0,
              "batteryReserveDurationHours": 1,
              "batteryImportMw": null,
              "batteryExportMw": null,
              "batteryUpgradeCostPerKw": null,
              "batteryCapacityPolicy": "maintained",
              "batteryMaintenanceCostMode": "priced",
              "batteryAugmentationCostPerKwh": 200,
              "batteryAnnualDegradationPct": 2,
              "batteryCycleFadePctPer1000": 3,
              "batteryAgingMode": "annual-throughput",
              "batteryCycleDepthExponent": 1.5,
              "batteryCalendarSocSensitivity": 0,
              "batteryUnaugmentedOmPct": 1.5,
              "batteryVariableOmPerMwh": 0,
              "batteryReservedPct": 0,
              "batteryContractRevenuePerKwYear": 0,
              "batteryContractYears": 0,
              "batteryContractCyclesPerYear": 0,
              "batteryAfterContract": "merchant",
              "batteryRaMw": null,
              "batteryRaRevenuePerKwYear": 0,
              "batteryRaYears": 0,
              "batteryRaStartHour": 16,
              "batteryRaDurationHours": 4,
              "batteryEnergyMarginMultiplier": 1,
              "batteryAnnualMarginTrendPct": 0,
              "batteryConnectionDelayYears": 0,
              "batteryFixedDevelopmentCostUsd": null,
              "batteryRouteKm": null,
              "batteryMaxRouteKm": null,
              "batteryRouteWidthM": 40,
              "batteryRouteCostPerKm": null,
              "batteryEnergizationYear": null,
              "batteryRetailStationPowerKw": 0,
              "batteryStationPowerTariff": "unpriced",
              "batteryStationPowerVoltage": "secondary",
              "batteryStationPowerNetting": "metered",
              "batteryStationReservationKw": null,
              "batteryStationEnergyRatePerKwh": null,
              "batteryStationDemandRatePerKwMonth": null,
              "batteryStationFixedCostPerDay": null,
              "batteryGuideLineItemId": "none",
              "batteryGuideTerminalItemId": "none",
              "batteryGuideCostMultiplier": 1,
              "batteryGuideContingencyPct": 20,
              "batteryGuideEscalationPct": 0,
              "batteryMaximumSlopePct": 5,
              "batteryReserveActivationFraction": 0.1,
              "batteryReserveAwardFraction": 1,
              "solarModuleEfficiencyPct": 21,
              "solarGroundCoverageRatio": 0.35,
              "solarFixedTiltDeg": null,
              "solarFixedAzimuthDeg": 180,
              "solarTrackingMaxAngleDeg": 60,
              "solarAxisAzimuthDeg": 0,
              "solarAxisTiltDeg": 0,
              "solarCrossAxisTiltDeg": 0,
              "solarHorizonElevationDeg": 0,
              "solarUsableLandPct": 80,
              "solarBoundarySetbackM": 20,
              "solarCapexPerKw": 1600,
              "solarFixedOmPerKwYear": 25,
              "solarVariableOmPerMwh": 0,
              "solarLifetimeYears": 30,
              "solarDiscountPct": 8,
              "solarDegradationPct": 0.5,
              "solarExportMw": null,
              "solarCurtailmentPct": 0,
              "solarUpgradeMillion": null,
              "solarPpaPerMwh": null,
              "solarPpaYears": 15,
              "solarReplacementPct": 10,
              "solarReplacementYear": 15,
              "windTurbine": "iea34",
              "windAirDensityMode": "reference",
              "windWakeModel": "allowance",
              "windTurbinePositionsM": null,
              "windArrayAzimuthDeg": 0,
              "windThrustCoefficient": 0.8,
              "windWakeExpansion": 0.05,
              "windWakeLossPct": 8,
              "windOtherLossPct": 5,
              "windSpacingDownwindD": 7,
              "windSpacingCrosswindD": 4,
              "windBoundarySetbackM": 500,
              "windUsableLandPct": 80,
              "windAccessMillion": null,
              "windCapexPerKw": 1700,
              "windFixedOmPerKwYear": 45,
              "windVariableOmPerMwh": 0,
              "windLifetimeYears": 30,
              "windDiscountPct": 8,
              "windDegradationPct": 0.2,
              "windExportMw": null,
              "windCurtailmentPct": 0,
              "windUpgradeMillion": null,
              "windPpaPerMwh": null,
              "windPpaYears": 15,
              "windReplacementPct": 10,
              "windReplacementYear": 15,
              "geoDepthScenario": "egs4500",
              "geoCostIndex": 1.15,
              "geoProductionMwPerWell": 5,
              "geoInjectionWellsPerProducer": 1,
              "geoDrillingSuccessPct": 80,
              "geoFieldSuccessPct": null,
              "geoFailedFieldTestWells": 2,
              "geoFailedFieldOtherMillion": 0,
              "geoSustainableMw": null,
              "geoPumpModel": "allowance",
              "geoProductionPressureBar": 30,
              "geoInjectionPressureBar": 20,
              "geoPumpEfficiencyPct": 75,
              "geoFluidDensityKgM3": 1000,
              "geoInitialProductionC": 180,
              "geoReinjectionC": 70,
              "geoThermalDeclineCYear": 0,
              "geoProductionPumpPct": 5,
              "geoReinjectionPumpPct": 3,
              "geoReinjectionRecoveryPct": 98,
              "geoFluidKgPerSecondPerMw": 15,
              "geoCapexPerKw": null,
              "geoFixedOmPerKwYear": null,
              "geoVariableOmPerMwh": 0,
              "geoLifetimeYears": 30,
              "geoDiscountPct": 8,
              "geoDegradationPct": 1,
              "geoExportMw": null,
              "geoCurtailmentPct": 0,
              "geoUpgradeMillion": null,
              "geoPpaPerMwh": null,
              "geoPpaYears": 15,
              "geoReplacementPct": 10,
              "geoReplacementYear": 15,
              "h2SolarRatio": null,
              "h2WindRatio": null,
              "h2StorageHours": 12,
              "h2StorageLossPctDay": 0,
              "h2RequiredBufferHours": null,
              "h2StorageCapexPerKg": 500,
              "h2CompressionKwhPerKg": 1.6,
              "h2CompressionCapexPerKgHour": 2500,
              "h2WaterLitersPerKg": 13.5,
              "h2WaterCostPerM3": 1.5,
              "h2WaterSupplyM3Day": null,
              "h2DeliveryKm": 0,
              "h2DeliveryUsdPerKgKm": null,
              "h2DeliveryLossPct": 0,
              "h2DeliveryCapacityKgHour": null,
              "h2OfftakeUsdPerKg": null,
              "h2OfftakeTonnesYear": null,
              "h2OfftakeHourlyShape": null,
              "h2ConnectionCapexMillion": null,
              "h2StorageCapacityKg": null,
              "h2ElectrolyzerMw": null,
              "h2CompressorMw": null,
              "h2CompressionMode": "entered",
              "h2InletBar": 30,
              "h2OutletBar": 350,
              "h2CompressionStages": 3,
              "h2CompressionTemperatureC": 25,
              "h2CompressorEfficiencyPct": 75,
              "h2CompressorMotorEfficiencyPct": 95,
              "h2Compressibility": 1,
              "h2MonthlyWaterM3Day": null,
              "h2WaterTankM3": 0,
              "h2WaterTankCapexPerM3": 500,
              "h2OutageStartDay": 180,
              "h2OutageHours": 0,
              "h2ForcedOutagePct": 0,
              "h2ForcedOutageBlockHours": 24,
              "h2OutageSeed": 2026,
              "h2DeliveryMode": "continuous",
              "h2TrailerPayloadKg": 500,
              "h2TrailerCount": 1,
              "h2TrailerSpeedKmh": 60,
              "h2TrailerHandlingHours": 2,
              "h2CustomerStorageKg": 1000,
              "h2TrailerCapexEach": null,
              "h2CustomerStorageCapexPerKg": 500,
              "h2DeliveryTargetPct": 95,
              "h2SearchMaxSolarRatio": 4,
              "h2SearchMaxWindRatio": 4,
              "h2SearchMaxStorageHours": 72,
              "hydroSource": "entered",
              "hydroMonthlyFlowM3s": null,
              "hydroMonthlyHeadM": null,
              "hydroGrossHeadM": null,
              "hydroRatedFlowM3s": null,
              "hydroHydraulicLossPct": 8,
              "hydroEfficiencyPct": 88,
              "hydroEnvironmentalFlowPct": 20,
              "hydroMinimumRiverFlowM3s": 0,
              "hydroDryYearFlowPct": 70,
              "hydroAvailabilityPct": 95,
              "hydroMinimumTurbineFlowPct": 10,
              "hydroEfficiencyModel": "constant",
              "hydroEfficiencyCurvePct": null,
              "hydroTailwaterRiseM": 0,
              "hydroTailwaterReferenceM3s": null,
              "hydroMaximumRiverFlowM3s": null,
              "hydroMonthlyReserveM3s": null,
              "bioSustainableWetTonnesYear": null,
              "bioMoisturePct": 30,
              "bioDryLhvMjKg": 18,
              "bioElectricEfficiencyPct": 25,
              "bioParasiticPct": 8,
              "bioAvailabilityPct": 85,
              "bioFeedstockUsdWetTonne": null,
              "bioHaulKm": null,
              "bioHaulUsdTonneKm": null,
              "bioSource": "entered",
              "bioFeedstockCategory": "ForestRes",
              "bioCompetingUsePct": null,
              "bioProcurementSharePct": 10,
              "bioMonthlySupplyWeights": null,
              "bioMonthlyMoisturePct": null,
              "bioStorageWetTonnes": 0,
              "bioStorageDryLossPctMonth": 0,
              "bioPreparationKwhWetTonne": 0,
              "bioPreparationImportPricePerMwh": null,
              "bioStorageCapexWetTonne": null,
              "processCapexPerKw": null,
              "processFixedOmPerKwYear": null,
              "processVariableOmPerMwh": 0,
              "processPowerPricePerMwh": null,
              "processDiscountPct": 7,
              "processLifetimeYears": 30,
              "loadPowerBasis": "it",
              "loadWorkloadClass": "colocation",
              "loadMustRunPct": 0,
              "loadFlexibleSharePct": 20,
              "loadFlexibleMaxDelayHours": 4,
              "loadFirmServiceMw": 99.8,
              "loadRackDensityKw": 30,
              "loadWhiteSpaceM2PerRack": 4,
              "loadBuildingGrossFactor": 2,
              "loadBuildingStories": 3,
              "loadBuildingCoveragePct": 45,
              "loadCoolingYardM2PerMwIt": 120,
              "loadElectricalYardM2PerMw": 80,
              "loadBackupYardM2PerMw": 80,
              "loadOtherYardAcres": 2,
              "loadCoolingMode": "constant",
              "loadCoolingPhysics": "linear",
              "loadNonCoolingOverheadPct": 8,
              "loadCoolingOversizePct": 25,
              "loadCoolingContingencyUnits": 1,
              "loadChilledWaterC": 7,
              "loadCoolingAuxPct": 2,
              "loadFreeCooling": "on",
              "loadEconomizerApproachC": 3,
              "loadTowerApproachC": 4,
              "loadTowerRangeC": 5,
              "loadTowerCycles": 5,
              "loadTowerLatentPct": 85,
              "loadTowerDriftPct": 0.002,
              "loadReferenceTempC": 25,
              "loadPuePerDegree": 0.01,
              "loadEconomizerPue": 1.1,
              "loadWetEnableTempC": 25,
              "loadWueHotPctPerDegree": 2,
              "loadWaterSupplyM3Day": null,
              "loadServiceCapacityMw": null,
              "loadServiceYear": null,
              "loadUpgradeCostMillion": null,
              "loadRedundancy": "n1",
              "loadModuleMw": 10,
              "loadIndependentFiberRoutes": null,
              "loadCriticalFractionPct": 100,
              "loadUpsMinutes": 15,
              "loadUpsReservePct": 20,
              "loadUpsEfficiencyPct": 95,
              "loadGeneratorMw": null,
              "loadGeneratorStartSeconds": 30,
              "loadBackupFuelLitres": null,
              "loadGeneratorLitresPerKwh": 0.26,
              "loadOutageHours": 24,
              "loadCostHorizonYears": 20,
              "loadCostDiscountPct": 8,
              "loadTariffEscalationPct": 0,
              "loadLandCostMillion": null,
              "loadBuildingCostMillion": null,
              "loadCoolingCostMillion": null,
              "loadWaterCostMillion": null,
              "loadFiberCostMillion": null,
              "loadBackupCostMillion": null,
              "loadOtherAnnualCostMillion": null,
              "loadDelayCostMillionPerYear": null,
              "loadRampYear1Pct": 100,
              "loadRampYear2Pct": 100,
              "loadRampYear3Pct": 100
            },
            "battery": {
              "durationHours": 4
            },
            "solarLossPct": 14,
            "windHubHeight": 110,
            "windSpecificPower": 280,
            "windLossPct": 13,
            "solarMount": "tracking",
            "geothermalSystem": "egs"
          },
          "summary": {
            "status": "provisional",
            "methodVersion": "2026-10-load-development-v17",
            "score": 60.1,
            "evidenceScore": 60.1,
            "evidenceCoveragePct": 70,
            "scoringEligibility": {
              "grid": true,
              "resource": true,
              "project": true,
              "boundary": true,
              "hourly": true,
              "operational": true,
              "blocked": false,
              "fit": true,
              "economics": true,
              "pathway": true,
              "exploratory": true,
              "negativeEconomics": false,
              "aggregation": "fixed-lower-bound"
            },
            "projectFit": "requires-confirmation",
            "checks": [
              {
                "id": "project-land",
                "label": "Project area at the requested capacity",
                "status": "pass",
                "observed": 15.45,
                "required": 11.12,
                "unit": "acres",
                "detail": "The entered area must accommodate the MW-dependent envelope. Area alone does not establish contiguity, setbacks, land rights or permits.",
                "evidence": "entered-scenario"
              },
              {
                "id": "load-service-capacity",
                "label": "Electrical service covers full-build demand",
                "status": "unknown",
                "observed": null,
                "required": 99.8,
                "unit": "MW",
                "detail": "Full-build cooling demand, historical stress and a larger declared firm requirement size service independently of mean utilization. A nearby substation or forecast does not reserve capacity.",
                "evidence": "unverified"
              },
              {
                "id": "load-service-date",
                "label": "Energization meets the target year",
                "status": "unknown",
                "observed": null,
                "required": 2030,
                "unit": "year",
                "detail": "The entered energization year must be no later than the target. An entered date remains subject to a utility agreement.",
                "evidence": "unverified"
              },
              {
                "id": "load-water",
                "label": "Water supply covers full-build peak day",
                "status": "unknown",
                "observed": null,
                "required": 792,
                "unit": "m³/day",
                "detail": "Compare supply with the largest full-build consecutive 24-hour requirement across the reference and prepared weather years. Nearby water and supplier plans are not allocations.",
                "evidence": "unverified"
              },
              {
                "id": "load-fiber",
                "label": "Required independent fiber routes",
                "status": "unknown",
                "observed": null,
                "required": 2,
                "unit": "routes",
                "detail": "Compare the entered independently routed connections with the explicit brief. Nearby carriers can share ducts; public proximity does not verify route diversity.",
                "evidence": "unverified"
              },
              {
                "id": "load-backup",
                "label": "Backup sustains the entered outage",
                "status": "unknown",
                "observed": null,
                "required": 24,
                "unit": "hours",
                "detail": "UPS bridging, post-contingency generator power and usable fuel must sustain the stated critical load. Unknown generator or fuel inputs do not establish service.",
                "evidence": "unverified"
              }
            ],
            "physics": {
              "powerBasis": "it",
              "itNameplateMw": 66,
              "facilityReferenceMw": 93.72,
              "operatingPeakMw": 84.348,
              "firmServiceRequirementMw": 99.8,
              "annualFacilityMwh": 738888.4800000705,
              "annualItMwh": 520344.00000008306,
              "fullBuildPeakDayM3": 792
            },
            "utility": {
              "mapStatus": "ambiguous",
              "mappedProviders": [
                "PG&E",
                "SVP"
              ],
              "excludedSpecialPurposeEntities": [
                "Power and Water Resource Pooling Authority"
              ],
              "scenarioProvider": "SVP",
              "selection": {
                "provider": {
                  "name": "Silicon Valley Power",
                  "acronym": "SVP",
                  "type": "POU"
                },
                "status": "conditional-user-scenario",
                "requested": "SVP",
                "explicitlySelected": true,
                "confirmed": false,
                "explanation": "The user selected this mapped utility for a conditional scenario. Other map intersections are retained; this is not confirmation of parcel service."
              },
              "providerConfirmed": false
            },
            "connection": {
              "pathway": {
                "version": "2026-10-load-service-pathways-v1",
                "requested": "auto",
                "effective": "bulk",
                "peakMw": 99.8,
                "thresholdMw": 20,
                "source": null,
                "confirmed": false,
                "label": "Dedicated bulk / subtransmission service to investigate",
                "basis": "For this regional screen, peak demand above 20 MW triggers dedicated bulk-service investigation. This is an explicit engineering-screen assumption, not a published utility threshold, service rule or capacity claim.",
                "limitations": "The utility determines the actual method of service from demand, location, reliability, expansion, cost and system studies. Small loads can also need dedicated service; large loads can have site-specific distribution solutions."
              },
              "score": null,
              "currentReservedServiceMw": null
            },
            "poi": {
              "name": "Fiberglas",
              "kv": 115,
              "distanceKm": 0.2887751588456137,
              "demandMw": 99.8,
              "capacityConfirmed": false,
              "owner": "SVP",
              "ownerMatchStatus": "matching-retail-owner",
              "ownershipGate": {
                "providerAcronym": "SVP",
                "providerName": "Silicon Valley Power",
                "status": "conditional-utility-owner-match",
                "matchedCount": 31,
                "unresolvedCount": 375,
                "differentUtilityCount": 351,
                "nearbyCount": 757,
                "utilityServiceConfirmed": false,
                "currentOwnershipConfirmed": false
              },
              "ownershipEvidenceKnown": false,
              "unresolvedNearbyContext": [
                {
                  "name": "Trimble",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 2.0670612208683727,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "FMC",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 3.6566593775659313,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Gish",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 3.7478981309322434,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "River Oaks",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.592429560796815,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Montague",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 4.991675654095526,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Nortech",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 5.405485806823315,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "San Jose Station B",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 5.4222342757915465,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                },
                {
                  "name": "Signetics",
                  "owner": "PG&E",
                  "kv": 115,
                  "distanceKm": 5.916301861924017,
                  "ownerMatchStatus": "different-retail-owner",
                  "eligibleForPreference": false
                }
              ]
            },
            "land": {
              "reportedInputAcres": 15.45,
              "estimatedRequiredAcres": 11.12,
              "fitRatio": 1.3893884892086332,
              "grossFloorAreaSqft": 189444.8233340911,
              "architecture": {
                "status": "modeled-scenario",
                "workloadClass": "colocation",
                "itNameplateMw": 66,
                "facilityReferenceMw": 93.72,
                "facilityDesignMw": 99.8,
                "racks": 2200,
                "whiteSpaceM2": 8800,
                "grossFloorAreaM2": 17600,
                "buildingFootprintM2": 5866.666666666667,
                "hallZoneM2": 13037.037037037036,
                "coolingYardM2": 7920,
                "electricalYardM2": 7984,
                "backupYardM2": 7984,
                "otherYardAcres": 2,
                "requiredAcres": 11.124375362726246,
                "acresPerMw": 0.16855114185948858,
                "basis": "IT nameplate determines rack count and cooling yard. Gross floor area is divided by floors; hall-zone coverage adds building access/setbacks. Separate electrical, backup and staging yards are then added. All area coefficients are explicit editable scenario assumptions.",
                "limitations": [
                  "Not an engineered parcel layout. Shape, easements, setbacks, fire access, zoning, height restrictions, soil and equipment clearances require a site plan.",
                  "Area coefficients are illustrative architecture assumptions, not calibrated measurements. More floors or denser racks do not guarantee planning permission or adequate cooling.",
                  "Electrical/backup yards use reference PUE power or a larger declared firm requirement; weather-driven equipment changes may require a larger yard."
                ],
                "sources": [
                  "https://www.energy.gov/cmei/femp/articles/best-practices-guide-energy-efficient-data-center-design",
                  "https://www.energy.ca.gov/powerplant/backup-generating-system/lafayette-backup-generating-facility"
                ]
              }
            },
            "deliveredBill": {
              "status": "scenario",
              "schedule": "SVP CB-6 non-TOU",
              "annualCostUsd": 106050439.1220384,
              "annualKwh": 738888480,
              "dollarsPerMwh": 143.52698951543866,
              "providerConfirmed": false,
              "eligibilityConfirmed": false,
              "alternatives": [
                {
                  "provider": "PG&E",
                  "voltage": "secondary",
                  "status": "scenario",
                  "annualCostUsd": 149629587.34588003,
                  "dollarsPerMwh": 202.50632050168116,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 142024022.44428,
                  "dollarsPerMwh": 192.21306907407734,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "PG&E",
                  "voltage": "transmission",
                  "status": "scenario",
                  "annualCostUsd": 111569409.82665,
                  "dollarsPerMwh": 150.99627730919556,
                  "eligibilityConfirmed": false
                },
                {
                  "provider": "SVP",
                  "voltage": "primary",
                  "status": "scenario",
                  "annualCostUsd": 106050439.1220384,
                  "dollarsPerMwh": 143.52698951543866,
                  "eligibilityConfirmed": false
                }
              ]
            },
            "requirementsRemainUnverified": [
              "load-service-capacity",
              "load-service-date",
              "load-water",
              "load-fiber",
              "load-backup"
            ],
            "dimensions": [
              {
                "id": "grid",
                "name": "Capacity-specific connection prospects",
                "score": 97.8,
                "coverage": 100,
                "weight": 25
              },
              {
                "id": "resource",
                "name": "Cooling & connectivity performance",
                "score": 92.2,
                "coverage": 55,
                "weight": 20
              },
              {
                "id": "development",
                "name": "Land & development",
                "score": 80.4,
                "coverage": 95,
                "weight": 20
              },
              {
                "id": "market",
                "name": "Site cost scenario",
                "score": 68.2,
                "coverage": 60,
                "weight": 25
              },
              {
                "id": "queue",
                "name": "Power delivery & timing evidence",
                "score": null,
                "coverage": 0,
                "weight": 10
              }
            ]
          },
          "comparison": {
            "historicalUtilityIsMapped": true,
            "scenarioMatchesHistoricalUtility": true,
            "historicalServiceKv": 60,
            "selectedMappedPoiKv": 115,
            "actualPoiMismatchIsDiagnosticOnly": true,
            "modeledFirmDemandVsReportedMaxMw": 0,
            "modeledItVsReportedItMw": 0,
            "referenceFacilityMw": 93.72,
            "reportedWorstCaseFacilityMw": 99.8,
            "reportedExpectedDemandMw": 60,
            "expectedDemandNotUsedAsAnnualLoadFactor": true,
            "serviceMvaRetainedSeparately": 100,
            "modeledVsReportedGrossFloorAreaRatio": 0.3292396491040007,
            "modeledRequiredVsReportedCampusAcresRatio": 0.7197411003236246,
            "interpretation": "Compare model semantics and explicit scenario assumptions. A floor-area or area-fit mismatch identifies the need for project architecture; it does not establish that the documented campus is infeasible. A nearby selected station need not be the historical utility connection."
          }
        }
      },
      "assertions": [
        {
          "id": "historical-utility-retained",
          "pass": true,
          "detail": "Named historical provider is present among map candidates; other genuine overlaps are retained. A failure needs a coordinate/territory review, not forced provider substitution."
        },
        {
          "id": "conditional-provider-only",
          "pass": true,
          "detail": "Explicit historical provider scenario can price a bill while parcel service stays unconfirmed."
        },
        {
          "id": "no-historical-service-reservation",
          "pass": true,
          "detail": "Historical campus power and age never populate current service capacity or energization commitments."
        },
        {
          "id": "bulk-pathway",
          "pass": true,
          "detail": "These documented96–99.8MW campuses need dedicated-service investigation; distribution forecasts do not establish their readiness."
        },
        {
          "id": "firm-demand-preserved",
          "pass": true,
          "detail": "A90% operating-load assumption must not shrink full-build service demand."
        },
        {
          "id": "it-nameplate-preserved",
          "pass": true,
          "detail": "ReportedITMW is distinct from facilityMW and referencePUE overhead."
        },
        {
          "id": "mva-not-converted",
          "pass": true,
          "detail": "ServiceMVA is reference context, never the modelMW input."
        },
        {
          "id": "tariff-is-conditional",
          "pass": true,
          "detail": "Published-rate annual costs remain conditional2026 scenarios, not historical or future bills."
        },
        {
          "id": "no-cheapest-provider-selection",
          "pass": true,
          "detail": "Named historical provider is used explicitly; no cheapest overlapping provider is inferred."
        },
        {
          "id": "poi-not-capacity",
          "pass": true,
          "detail": "MappedkV and station proximity do not confirm spareMW or historical circuit diversity."
        },
        {
          "id": "poi-respects-conditional-utility",
          "pass": true,
          "detail": "A preferred mapped station must match the named conditional retail utility; unknown, joint and different-owner stations remain unresolved nearby context."
        },
        {
          "id": "map-owner-not-current-service",
          "pass": true,
          "detail": "Reviewed inventory ownership is not current ownership confirmation or parcel retail service eligibility."
        }
      ],
      "interpretation": "The 2023 tracked revision documents66 MW IT,99 MW suite peak+0.8 MW administrative demand, design annual PUE 1.42 and larger 15.45-acre project boundary. Earlier 576,120 ft² and the sentence claiming no cooling water are deleted; they are not imported as current facts. Reported 60 MW expected leased demand is not a measured annual capacity factor."
    }
  ]
}